Seitenansicht 15
10
Installation
2.7 D/A Output Configuration
The ACL-6126‘s output channels can be configured as different analog
output styles, and they are dependent on D/A converter's reference
voltage source and output mode( Bipolar or Unipolar). The reference
voltage can be generated internally or by external reference voltage
from the Reference Voltage Input ( REF.IN) of connector P1. Each
output channel and its corresponding jumpers are listed as follows.
Channel NO. Corresponding Jumper
CH0 JP1-3
CH1 JP2-3
CH2 JP3-3
CH3 JP4-3
CH4 JP5-3
CH5 JP6-3
The jumper settings for each output channel are illustrated as below
Figure 2.4 . The internal -5V is set as default reference voltage.
Reference
Voltage
Source
External Ref. -10V Ref.
-5V Ref.
( default )
Jumper
Setting
EXT
-5V
-10V
EXT
-5V
-10V
EXT
-5V
-10V
Figure 2.4 Reference Voltage Source