cExpress-HL User’s Manual Manual Revision: 1.01 Revision Date: September 23, 2014 Part Number: 50-1J049-1010
Page 10 cExpress-HL 2.16 Functional Diagram RTD2136RSoC“Haswell-ULT”i217LMPCA9535SMBus4x GP0GP I2C1333/1600 MHz1~8 GB DDR3LSPI4x GPI60-pin4x P
cExpress-HL Page 11 2.17 Mechanical Drawing Top ViewSide ViewAll tolerances ± 0.05 mmOther tolerances ± 0.2 mmconnectors on bottom side
Page 12 cExpress-HL 3 Pinouts and Signal Descriptions 3.1 AB / CD Pin Definitions The cExpress-HL is a Type 6 module supporting USB 3.0 and DDI c
cExpress-HL Page 13 Row A Row B Row C Row D Pin Name Pin Name Pin Name Pin Name A36 USB6- B36 USB7- C36 DDI3_CTRLCLK_AUX+ D36 DDI1_PAIR3
Page 14 cExpress-HL Row A Row B Row C Row D Pin Name Pin Name Pin Name Pin Name A81 LVDS_A_CK+ B81 LVDS_B_CK+ C81 PEG_RX9+ D81 PEG_TX9+
cExpress-HL Page 15 3.2 Signal Description Terminology The following terms are used in the COM Express AB/CD Signal Descriptions below. I Inpu
Page 16 cExpress-HL 3.3 AB Signal Descriptions 3.3.1 Audio Signals Signal Pin # Description I/O PU/PD Comment AC_RST# / HDA_RST# A30 Reset
cExpress-HL Page 17 3.3.3 LVDS Signal Pin # Description I/O PU/PD Comment LVDS_A0+ LVDS_A0- LVDS_A1+ LVDS_A1- LVDS_A2+ LVDS_A2- LVDS_A3
Page 18 cExpress-HL 3.3.5 Serial ATA 3.3.6 PCI Express Signal Pin # Description I/O PU/PD Comment PCIE_TX0+ PCIE_TX0- A68 A69 PCI Express
cExpress-HL Page 19 Signal Pin # Description I/O PU/PD Comment PCIE_RX5+ PCIE_RX5- B52 B53 PCI Express channel 5, Receive Input differential
Page 2 cExpress-HL Revision History Revision Description Date By 1.00 Initial release 2014-07-28 JC 1.01 Add BIOS Checkpoints, Beep Codes; r
Page 20 cExpress-HL Signal Pin # Description I/O PU/PD Comment USB_2_3_OC# A44 USB over-current sense, USB ports 2 and 3. A pull-up for this
cExpress-HL Page 21 3.3.12 Miscellaneous Signal Pin # Description I/O PU/PD Comment SPKR B32 Output for audio enunciator, the “speaker” in
Page 22 cExpress-HL Signal Pin # Description I/O PU/PD Comment GPO[3] B63 General purpose output pins. O 3.3V After hardware RESET outpu
cExpress-HL Page 23 Signal Pin # Description I/O PU/PD Comment LID# LID button. Low active signal used by the ACPI operating system for a L
Page 24 cExpress-HL 3.4 CD Signal Descriptions 3.4.1 USB 3.0 extension Signal Pin Description I/O PU/PD Comment USB_SSRX0- USB_SSRX0+ C3 C4
cExpress-HL Page 25 3.4.3 DDI Channels DDI 1 Signal Pin Description I/O PU/PD Comment DDI1_PAIR0+ DDI1_PAIR0- DDI1_PAIR1+ DDI1_PAIR1- DDI1_PA
Page 26 cExpress-HL DDI 2 Signal Pin Description I/O PU/PD Comment DDI2_PAIR0+ DDI2_PAIR0- DDI2_PAIR1+ DDI2_PAIR1- DDI2_PAIR2+ DDI2_PAIR2- DDI
cExpress-HL Page 27 3.4.4 DDI to DP/HDMI/SDVO Mapping Pin Pin Name DP HDMI \ DVI D26 DDI1_PAIR0+ DP1_LANE0+ TMDS1_DATA2+ D27 DDI1_PAIR0- DP1
Page 28 cExpress-HL 3.4.5 PCI Express Graphics x16 (PEG) Signal Pin Description I/O PU/PD Comment PEG_RX0+ PEG_RX0- PEG_RX1+ PEG_RX1- PEG
cExpress-HL Page 29 Signal Pin Description I/O PU/PD Comment PEG_TX15+ PEG_TX15- D101 D102 PEG_LANE_RV# D54 PCI Express Graphics lane rever
cExpress-HL Page 3 Preface Copyright 2014 ADLINK Technology, Inc. This document contains proprietary information protected by copyright. All right
Page 30 cExpress-HL 4 Connector Pinouts on Module This chapter describes connectors and pinouts, LEDs and switches that are used on the module but
cExpress-HL Page 31 4.1 40-pin Debug Connector ¾ FPC Connector Type: FCI 59GF Flex 10042867 ¾ Pin Orientation ¾ cExpress-HL and the DB40 D
Page 32 cExpress-HL ¾ 40-pin Debug Connector Pin Definition on the COM Express Module Pin Interface Signal Remark Pin Interface Signal Re
cExpress-HL Page 33 4.2 Status LEDs To facilitate easier maintenance, status LED’s are mounted on the board. ¾ LED Descriptions Name Color Con
Page 34 cExpress-HL 4.3 XDP Debug header The debug port is a connection into a target-system environment that provides access to JTAG, run control
cExpress-HL Page 35 4.4 Fan Connector ¾ Connector Type: JVE 24W1125A-04M00 ¾ Pin Assignment Name Signal Description 1 BMC_FAN_OUT FAN_PWMOUT 2
Page 36 cExpress-HL 5 Smart Embedded Management Agent (SEMA) The onboard microcontroller (BMC) implements power sequencing and Smart Embedded Mana
cExpress-HL Page 37 5.1 Board Specific SEMA Functions 5.1.1 Voltages The BMC of the cExpress-HL implements a voltage monitor and samples several
Page 38 cExpress-HL 5.1.4 Exception Codes In case of an error, the BMC drives a blinking code on the blue Status LED (LED1). The same error code i
cExpress-HL Page 39 6 System Resources 6.1 System Memory Map Address Range (decimal) Address Range (hex) Size Description (4GB-2MB) FFE00000
Page 4 cExpress-HL Table of Contents Revision History ...
Page 40 cExpress-HL 6.3 I/O Map Hex Range Device 000-01F DMA controller 1, 8237A-5 equivalent 020-02D and 030-03F Interrupt controller 1, 8259
cExpress-HL Page 41 Hex Range Device 3BC-3BE Reserved for parallel port 3C0-3DF VGA registers 3E0-3EF Available 3F0-3F7 Available 3F8-3FF Serial
Page 42 cExpress-HL 6.4 Interrupt Request (IRQ) Lines PIC Mode IRQ# Typical Intterupt Resource Connected to Pin Available 0 Counter 0 N/A No
cExpress-HL Page 43 IRQ# Typical Intterupt Resource Connected to Pin Available 16 N/A Intel HDA, PCIE Port 0/1/2/3 EHCI Conterller #2 , I.G.D
Page 44 cExpress-HL 6.5 PCI Configuration Space Map Bus Number Device Number Function Number Routing Description 00h 00h 00h N/A Intel host
cExpress-HL Page 45 6.6 PCI Interrupt Routing Map INT Line Audio Controller xHCI Controller ME Controller #1 GbEt Controller HDA Controller Int0
Page 46 cExpress-HL 7 BIOS Setup 7.1 Menu Structure This section presents the six primary menus of the BIOS Setup Utility. Use the following tabl
cExpress-HL Page 47 7.2 Main The Main Menu provides read-only information about your system and also allows you to set the System Date and Time. R
Page 48 cExpress-HL 7.2.6 System Management 7.2.6.1 System Management > Board Information Board Information Info only SMC Firmware Read on
cExpress-HL Page 49 Feature Options Description V1.00 Read only Display actual V1.00 voltage V3.30 Read only Display actual V3.30 volta
cExpress-HL Page 5 5.1 Board Specific SEMA Functions ...
Page 50 cExpress-HL 7.2.6.7 System Management > LVDS Backlight Feature Options Description LVDS Backlight Info only LVDS Backlight Brig
cExpress-HL Page 51 7.3 Advanced This menu contains the settings for most of the user interfaces in the system. 7.3.1 CPU Feature Options Des
Page 52 cExpress-HL Feature Options Description CPU C3 Report Disabled Enabled Enable / Disable CPU C3 report to OS. CPU C6 Report Disabled
cExpress-HL Page 53 7.3.3 Graphics Feature Options Description Graphics Info only IGFX VBIOS Version Info only Display VBIOS Version. IGfx
Page 54 cExpress-HL Feature Options Description 1280X1024 1400X1050 1600X1200 1366X768 1680X1050 1920X1200 1440X900 1600X900 1024X768 LVDS2 12
cExpress-HL Page 55 Feature Options Description SATA Port Configuration Submenu Software Feature Mask Configuration Info only RAID0 Enabl
Page 56 cExpress-HL Feature Options Description SATA Device Type Hard Disk Drive Sold State Drive Identify the SATA port is connected to Soli
cExpress-HL Page 57 7.3.5.1 USB > Chipset USB Configuration Feature Options Description USB Configuration Info only USB Precondition Dis
Page 58 cExpress-HL Feature Options Description USB Configure Enabled Disabled Enable/Disable USB Configure function. PET Progress Enabled D
cExpress-HL Page 59 Feature Options Description 4096 Bytes PCI Express Link Register Settings Info only ASPM Support WARNING: Enabling ASPM m
Page 6 cExpress-HL 1 Introduction The cExpress-HL is a COM Express® COM.0 R2.1 Type 6 Compact size module supporting the 64-bit 4th Generation Int
Page 60 cExpress-HL PCI and PCIe > PCIe Configuration > PCI Express Port x Feature Options Description PCI Express Port x Enabled Dis
cExpress-HL Page 61 Feature Options Description Snoop Latency Ocerrid Disable Manual Auto Snoop Latency Ocerride for PCH PCIE. Non Snoop Late
Page 62 cExpress-HL Feature Options Description XP, the the "OS shutdown message" will be shown when the system is shutdown. ACPI Sl
cExpress-HL Page 63 7.3.11.1 Serial Port Console > Console Redirection Settings Feature Options Description COM1/ COM2/ COM3/ COM4 Console
Page 64 cExpress-HL Feature Options Description Active Cooling Trip Point Disabled 40 C 50 C 60 C 70 C BMC Default Active Cooling Trip Point.
cExpress-HL Page 65 7.3.13.2 Miscellaneous > Trusted Computing Feature Options Description Coniguration Info only Security Device Support
Page 66 cExpress-HL 7.4.1.2 Boot Configuration > CSM Parameters Feature Options Description Launch CSM Enable Disable This option control
cExpress-HL Page 67 7.6 Save & Exit 7.6.1 Save and Exit > Reset Options Feature Options Description Save Changes and Reset Save cha
Page 68 cExpress-HL 8 BIOS Checkpoints, Beep Codes This section of this document lists checkpoints and beep codes generated by AMI Aptio BIOS. The
cExpress-HL Page 69 8.1 Status Code Ranges Status Code Range Description 0x01 – 0x0F SEC Status Codes & Errors 0x10 – 0x2F PEI executio
cExpress-HL Page 7 2 Specifications 2.1 Core System ¾ CPU: 4th Generation Intel® Core™ processor SoC (formerly "Haswell-ULT", Ultra Lo
Page 70 cExpress-HL 8.2.2 SEC Beep Codes None 8.2.3 PEI Status Codes Status Code Description Progress Codes 0x10 PEI Core is started 0x11
cExpress-HL Page 71 Status Code Description 0x3C Post-Memory South Bridge initialization (South Bridge module specific) 0x3D Post-Memory So
Page 72 cExpress-HL Status Code Description 0xF2 Recovery process started 0xF3 Recovery firmware image is found 0xF4 Recovery firmware i
cExpress-HL Page 73 Status Code Description 0x6C North Bridge DXE initialization (North Bridge module specific) 0x6D North Bridge DXE ini
Page 74 cExpress-HL Status Code Description 0xA4 SCSI initialization is started 0xA5 SCSI Reset 0xA6 SCSI Detect 0xA7 SCSI Enable 0x
cExpress-HL Page 75 Status Code Description 0xDC Reset protocol is not available 8.2.6 DXE Beep Codes # of Beeps Description 4 Some of
Page 76 cExpress-HL 9 Mechanical Information 9.1 Board-to-Board Connectors To allow for different stacking heights, the receptacles for COM Expre
cExpress-HL Page 77 9.2 Thermal Solution 9.2.1 Heat Spreaders The function of the heat spreader is to ensure an identical mechanical profile for
Page 78 cExpress-HL Step 4: Use the four M2.5, L=6mm screws provided to fasten the heatsink to the module. Step 5: Place the COM Express modu
cExpress-HL Page 79 9.3 Mounting Methods There are several standard ways to mount the COM Express module with a thermal solution onto a carrier bo
Page 8 cExpress-HL 2.4 Audio ¾ Integrated: Intel® HD Audio integrated in PCH QM87 ¾ Codec: Realtek ALC886 on Express-BASE6 2.5 LAN ¾ Integrate
Page 80 cExpress-HL 9.4 Standoff Types The standoffs available for Top and Bottom mounting methods are shown below. Note that threaded standoffs a
cExpress-HL Page 81 Safety Instructions Read and follow all instructions marked on the product and in the documentation before you operate your sys
Page 82 cExpress-HL Getting Service ADLINK Technology, Inc. Address: 9F, No.166 Jian Yi Road, Zhonghe District New Taipei City 235, Taiwan Tel:
cExpress-HL Page 83 ADLINK Technology, Inc. (French Liaison Office) Address: 6 allée de Londres, Immeuble Ceylan 91940 Les Ulis, France Tel:
cExpress-HL Page 9 2.11 Power Specifications ¾ Power Modes: AT and ATX mode (AT mode start controlled by SMC) ¾ Standard Voltage Input: A
Kommentare zu diesen Handbüchern