Signal Connections 35
ADLINK Technology Inc. PCI-9524
Copyright 2008 User’s Manual
Figure 3-5: Connecting to a six-terminal load-cell transducer
using a six-wire connection
+Vex
+Vo
-Vex
-Vo
Load-cell Transducer
+Sense
-Sense
AIn+
AIn-
VEXn+
VEX_SENn+
VEXn-
VEX_SENn-
NC
NC
Whether to use a six-wire connection is dependent on the imped-
ance of the load-cell transducers you are using, length of the wir-
ing cable, wire-gauge inside the cable, and the required
measurement accuracy. We recommend you to use a six-wire
connection as the default connection method for high-accuracy
load-cell transducers.
To add remote-sense capability to a four-terminal load-cell trans-
ducer, simply run two separate sense-wires, and join them
together with the excitation wires at the transducer's excitation ter-
minals.