Seitenansicht 41
38 Power Supply Unit
Power Fail Signal: available at [FAL#] pin
Status LED: <green> means valid input voltage; <amber> means a
critical fault.
Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin
Power OK: Installed at all outputs
Leakage Current: 1.18mA at 254Vac/60Hz
Output Characteristics
Output Current (A)
Output
Voltage
Min. Max. Typ. Peak.
5V
0 40.0 25.0
3.3V
0 40 20 –
12V
0 5.5 4
-12V
0 2 1 –
Over Load Protection: fully protected against output overload or short circuit,
typical 120% max. load
Over Current Protection: installed at each rail
o Output Wattage: Typ. 250W continuous.
o Output Connector: CompactPCI 47-pin power connector.
o Line Regulation: Max. ±10mV
o Load Regulation: 3.3V & 5V: ± 10mV, +12V: ± 30mV & -12V: -380
mV.
o Noise & Ripple: 60 mV@5V and 3.3V output; 120mV@.± 12V
output.
o OVP: Built-in at all outputs.
o Adjustability: Available at VO1, 2 & 3.
o Output Trim: Electrical trim available at VO1/VO2 [ADJ #].
o Remote Sensing: Available at VO1, VO2 & VO3.
o Hot-Swap: Available.
o N+1 Redundancy: Installed with internal OR-ing diodes at all outputs
for N+1 redundancy operation.
o Current Sharing: Third-wire current sharing at VO1,2 &3.
o Power OK Signal: Available for all output.