Operation Theory 41
When an external trigger signal occurs before the first M scans of data are
converted, the amount of stored data could be fewer than the originally
specified amount of DIV_counter * M_counter, as illustrated in fig 12. This
situation can be avoided by setting
M_enable.
If
M_enable
is set to 1, the
trigger signal will be ignored until the first M scans of data are converted, and it
assures user of obtaining M scans of data under pre-trigger mode, as
illustrated in fig 13. However, if
M_enable
is set to 0, the trigger signal will be
accepted in any time, as illustrated in fig 12. Note that the total amount of
stored data is still always a multiple of DIV_counter (number of samples per
scan) because the data acquisition won’t stop until a scan is completed.
A
cquisition_in_progress
Scan_start
A
D_conversion
Scan_in_progress
(SSH_OUT)(pin47)
(M_Counter = M = 3, DIV_Counter=4, SC_Counter=0)
A
cquired & stored data
(2 scans)
O
p
eration start
ExtTrg(pin46)
Figure 12: Pre-trigger with M_enable = 0 (trigger occurs before M scans)