Operation Theory 43
(M_Counter=M=3, DIV_Counter=4, SC_Counter=N=1)
A
cquisition_in_progress
Scan_start
A
D_conversion
Scan_in_progress
(
SSH_OUT
)(pin47)
Aq
uired data
A
cquired & stored data
(M+N scans)
O
p
eration start
ExtTrg(pin46)
M scans before
trigger
N scans
after trigger
Trigger signals which occur in the shadow
region(the first M scans) will be ignored
The first M scans
Figure 14: Middle trigger with M_enable = 1
If an external trigger event occurs when a scan is in progress, the stored N
scans of data would include this scan.