Seitenansicht 74
C++ Library 65
6.8.2 _9116_AD_Set_SI
@ Description
Set SI_Counter value for programmable scan acquisition mode.
@ Syntax
C/C++ (DOS)
int _9116_AD_Set_SI( I16 card_number, U32 counter_value )
@ Argument
card_number:
the card number of the cPCI-9116 to be initialized,
totally 4 cards can be initialized, valid card
numbers are CARD_1, CARD_2, CARD_3,
CARD_4.
Counter_value:
the SI_Counter value. Range: 96 through to
16777215
@ Return Code
ERR_NoError
ERR_BoardNoInit
6.8.3 _9116_AD_Set_SI2
@ Description
Set SI2_Counter value for programmable scan acquisition mode.
@ Syntax
C/C++ (DOS)
int _9116_AD_Set_SI2( I16 card_number, U32 counter_value )
@ Argument
card_number:
the card number of the cPCI-9116 to be initialized,
totally 4 cards can be initialized, valid card
numbers are CARD_1, CARD_2, CARD_3,
CARD_4.
Counter_value:
the SI2_Counter value. Range: 96 through to
65536
@ Return Code
ERR_NoError
ERR_BoardNoInit